EGP80 Electronic Grade Panelboard
Technical Specifications The electrical industry's first
Electronic Grade panelboard
FEATURES
The electrical industry's first Electronic Grade panelboard, Current Technology's patented and innovative EGP integrate Current Technology's respected UL 1283 high frequency range power filter and UL 1449 high performance suppression system with your choice of UL 67 listed GE, Siemens, Square D or Cutler-Hammer/Westinghouse non-linear six-wire panelboards. Standard EGP features include:

UL 1449 High Performance Suppression System: Advanced seamless technology integrates arrays of matched non-linear voltage dependent metal oxide varistors for maximum performance and proven reliability. EGPs provide bi-directional, bi-polar power conditioning with a tested single-pulse surge current capacity in excess of 160,000 amps per phase and a repetitive 10,000 amp surge current capacity of 2,500 impulses to assure maximum protection of valuable assets.

UL 1283 High Frequency Extended Range Power Filter: Unique filtering techniques combine with tight voltage clamping to provide optimum protection. Bi-directional, bi-polar line control yields broad range sine wave filtering to remove low-level surges, sharp wavefronts and error-producing high frequency noise bursts.

Integral Breakers for Suppression/Filter System: Integral suppression/filter system and three pole circuit breaker provides increased safety and the most cost-effective means of installation to achieve optimum performance

200% Rated Copper Neutral Bus: A 200% rated copper neutral bus eliminates harmful neutral overheating proliferated by non-linear loads

Safety Ground Bus: Incorporating an Al/Cu-rated mechanical lug at input, the safety ground bus accommodates connections equal to the number of branch breaker positions

Insulated Isolated Ground Bus: The insulated isolated ground bus eliminates cross-interference between safety ground and the isolated ground associated with sensitive electronic equipment

Ten Mode Diagnostic Test Point: The industry's first integral test point allows easy Diagnostic Test Set connection for real time testing and monitoring of system integrity using Current Technology's exclusive DTS-2 Diagnostic Test Set

Main Lug/Main Breaker Configurations: General Electric, Siemens, Square D and Cutler-Hammer/Westinghouse main lug or main breaker panel configurations are available to meet the requirements of any distribution system

Customer-Specified Breaker Layout: Single, two- or three-pole breaker configuration in accordance with exact customer specifications

Status Indicators: Indicate suppression and overcurrent status

Suppression Filter Systems Interconnections: Made with #8 AWG copper hypalon conductor with compression lugs and bolted to low impedance corrosion-resistant, tin-plated bus to ensure lowest possible impedance

Warranty: Five Years, suppression filter assembly and panelboard including breakers

Data Sheet
The data sheet is also available in *.pdf format - you can print it or right-click above and choose "Save Link As" to download it to your hard drive.

INDUSTRY STANDARDS CERTIFICATION

standard

description

UL 1449

Underwriters Laboratories standard that establishes requirements for surge suppression safety and performance. Commonly recognized as a benchmark test for product comparison

UL 1283

Underwriters Laboratories standard dictating requirements for electromagnetic interference (EMI) filters installed on, or connected to, 600V or lower potential circuits installed in accordance with the National Electrical Code. Also covers filters used to attenuate unwanted high frequency signals generated from electromagnetic sources

CUL

Canadian version of Underwriters Laboratories

NEMA LS-1

The specification format guideline published by the National Electrical Manufacturers Association for specifiers and customers investigating Low Voltage Surge Protection Devices

UL 67

Underwriters Laboratories recognized standard for the manufacture of electric panelboards rated 600 volts or less. UL 67 also dictates the use of Low Voltage AC Power Switching Devices and Fused Power Circuit Devices in panelboards

UL50

 

CSA

Canadian Standards Association's guidelines for compliance with general Canadian Electrical Code requirements for bonding and ground/protective ground of electrical equipment and surge/transient voltage suppressors

STANDARD MODEL NUMBERS
EGP1 80-120/240-MLO-2/3 4-5 6 EGP1 80-120/208-MB-2/3 4-5 6
EGP1 80-120/240-MB-2/3 4-5 6 EGP1 80-277/480-MLO-2/3 4-5 6
EGP1 80-120/208-MLO-2/3 4-5 6 EGP1 80-277/480-MB-2/3 4-5 6

NOTES:
1
Insert G for General Electric, I for Siemens, S for Square D, or W for Cutler-Hammer/Westing-house; MB = main breaker or MLO = main lug only;
2
insert ampere rating (100, 125, 225, 400, 600);
3
insert 1 for single phase or 3 for three phase;
4
insert total number of branch circuit positions including spaces;
5
insert F for flush mount or S for surface mount and
6
insert T for top feed or B for bottom feed plus option suffix(es). Example: EGPG-120/240-MB-100/112-FT or EGPS-120/208-MLO-225/342-SB or EGPW-277/480-MB-400/384-ST-FCC.

SINGLE PULSE SURGE CURRENT CAPACITY

Protection mode

Single pulse surge current
capacity per mode

Line-to-Neutral

>80,000 amps

Line-to-Ground

>80,000 amps

Neutral-to-Ground

>80,000 amps

Line-to-Line

>80,000 amps

Per Phase

>160,000 amps

In compliance with NEMA LS 1-1992, paragraphs 2.2.7, 2.2.9 and 3.9, Current Technology suppression filter systems are single pulse surge current tested in all modes at currents up to 150% of the product design rating by an industry-recognized independent test laboratory. Single pulse surge current capacities of 200,000 amps or less are established by single-unit testing of all components within each mode. Due to present industry test equipment limitations, single pulse surge current capacities over 200,000 amps are established via testing of individual components or sub-assemblies within a mode.

REPETITIVE SURGE CURRENT CAPACITY

Protection mode

Minimum tested impulses per mode

Line-to-Neutral

>3,500

Line-to-Ground

>3,500

Neutral-to-Ground

>3,500

Line-to-Line

>3,500

Per ANSI/IEEE C62.41-1991 and ANSI/IEEE C62.45-1992, all Current Technology suppression filter systems are repetitive surge current capacity tested in every mode utilizing a 1.2 X 50m sec 20KV open circuit voltage, 8 X 20 m sec 10 KA short circuit current Category C3 bi-wave at one minute internals without suffering either performance degradation or more than 10% deviation of clamping voltage at a specified surge current.

EMI/RFI NOISE REDUCTION VALUES

Multiple unit installation

Frequency

Single unit installation

51 dB

100 KHz

34 dB

94 dB

1 MHz

51 dB

114 dB

10 MHz

54 dB

120 dB

100 MHz

48 dB

All Current Technology suppression filter systems EMI-RFI noise rejection or attenuation values are in compliance with test and evaluation procedures outlined in NEMA LS 1-1992, paragraphs 2.2.11 and 3.11.

MAXIMUM CONTINUOUS OPERATING VOLTAGE (MOV)

Voltage

MCOV

120V

150V

240V

275V

277V

320V

480V

600V

All Current Technology suppression filter systems maximum continuous operating voltages are in compliance with test and evaluation procedures outlined in NEMA L 1-1992, paragraphs 2.2.6 and 3.6.

TYPICAL VOLTAGE CLAMPING DATA

Voltage

Protection Mode

A3 Ringwave

B3 Ringwave

B3/C1 Comb. Wave

C3 Comb. Wave

120/208

L-N

210

260

380

480

120/208

L-G

350

365

370

540

120/208

N-G

250

290

360

520

120/208

L-L

360

480

700

810

277/480

L-N

460

580

835

980

277/480

L-G

800

755

765

990

277/480

N-G

500

570

785

1050

277/480

L-L

805

1040

1555

1780

All Current Technology suppression filter systems clamping voltages are in compliance with test and evaluation procedures outlined in NEMA LS 1-1992, paragraphs 2.210 and 3.10. Values indicate typical clamping voltage data for models with integral fused disconnect (DF).

OPTIONS

Option

Order Suffix

Double form "C" dry contacts
-FCC
DTS-2 Diagnostic Test Set
-DTS
StatusWatch diagnostic monitoring
-SW
StatusWatch with display event counters
-SWC
All StatusWatch diagnostic monitoring options include double form "C" dry contacts, audible alarm, alarm silence/test and status indicator lights.

Ask an Engineer if you have any questions regarding this or other Current Technology products.

BACK

For more information about these or any other surge protection products or to speak with one of our sales reps, please contact us.